News & Events | Downloads | Contact | About us | Careers
  • Applications
    • In-line 100% container closure integrity inspection
    • In process control of headspace oxygen
    • In-line vacuum leak detection
    • In-line moisture determination of lyophilized vials
    • Nitrogen purge optimization and qualification
    • Headspace oxygen stability studies
    • Container closure integrity testing
    • Packaging permeation studies
    • Lyo chamber moisture mapping
    • Lyo cycle optimization
    • Lyo product stability studies
    • Water activity measurements
  • Headspace Systems
    • PULSAR Headspace Inspection System
    • PULSAR Headspace CCI Inspection Lease System
    • FMS-Oxygen Headspace Analyzer
    • FMS-Moisture/Pressure Headspace Analyzer
    • FMS-Carbon Dioxide Headspace Analyzer
    • FMS-Water Activity Analyzer
    • FMS-Flexible Bag Headspace Analyzer
  • Measurement Services
    • Laboratory Measurement Services
    • On-Site Measurement Services
    • Benchtop Equipment Lease
    • Automated Inspection Machine Lease
 

In-line Moisture Determination of Lyophilized Vials

Moisture Determination
Residual product moisture content is a critical parameter when considering the stability and shelf life of lyophilized pharmaceutical product, sterile powders, or solid dosage product.  Consequently, moisture analysis is performed in product and process development, as well as in commercial manufacturing to specify and control the maximum allowable moisture content.  This is traditionally performed using Karl Fischer titration or thermo-gravimetric analysis (TGA) methods, which are destructive and labor & time intensive.  Replacing these slow traditional methods with a rapid non-destructive method would streamline moisture analysis efforts and help improve the quality of finished product.
.
Headspace Moisture Analysis
Laser-based headspace inspection utilizing frequency modulation spectroscopy (FMS) is a rapid analytical method used for the analysis and inspection of finished sterile drug product.  Quantifying the physical conditions in the headspace of sterile containers enables the monitoring of critical quality parameters and gives detailed insight into the process.  In particular, quantifying the amount of water vapor in the headspace of freeze-dried vials with an optical method enables rapid non-destructive moisture determination.  Studies have demonstrated that the amount of headspace water vapor directly correlates to the lyo cake moisture content.  Stability studies have shown that the degradation of the active pharmaceutical ingredient correlates to the initial water vapor concentration present in the freeze-dried vial. Applications of headspace moisture analysis for freeze dried product include cycle optimization, lyo chamber moisture distribution mapping, and 100% moisture inspection of commercial freeze-dried product.
.

Related Material

Using Laser-Based Headspace Moisture Analysis for Rapid Nondestructive Moisture Determination of Sterile Freeze-Dried Product